Do you manufacture an acrylic sheet that meets ASTM-D-1547 Type II / L-P-507 Type II?

These standards were used by the DoD, described acrylic extruded sheet, and have been obsolete for many years. ASTM-D-1547 was withdrawn in 1988. According to that standard, Type II sheet is heat-resistant, made with Grade 8 molding compounds as specified in ASTM 788. ASTM 788 Grade 8 states minimum DTL test of 85°C and tensile strength of 9000 psi. ACRYLITE® sheet products are manufactured with a molding compound that meets these requirements.