Electrical Property Method Result
Dielectric Strength    
Short Time (0.125”) D 149 430 volts/mil (17 KV/mm)
Dielectric Constant    
60 Hertz D 150 3.6
1,000 Hertz D 150 3.3
1,000,000 Hertz D 150 2.8
Dissipation Factor    
60 Hertz D 150 0.06
1,000 Hertz D 150 0.04
1,000,000 Hertz D 150 0.02
Volume Resistivity D 257 10*16 ohm-cm
Surface Resistivity D 257 10*15 ohms